hydrostop-pu_0323_eng

HELPFUL TIPS - NOTES • Mix well before use. • Waterproof all vertical surfaces around the roof (parapet walls), their entire height. • Avoid exceeding thicknesses of 0.5mm per coat. • Low ambient temperatures delay the final curing time while high ambient temperatures speed up the curing process. • Avoid applying the product in high humidity conditions or when there is possibility of rain within the next 24 hours. V.O.C. (Volatile Organic Compound): Limit value of maximum V.O.C. content per EU (Directive 2004/42/EC) for the specific product (Category A/c: ‘Coatings for exterior walls of mineral substrate’, Type WB): 40gr/lt (2010). The ready to use product contains maximum 10gr/lt V.O.C. Technical specifications (Measurement conditions 23°C and 50% R.H.) Form - Color Viscous paste - White Composition Hybrid Dispersion System Density 1.35±0.05kg/lt Elongation at break >400% (ASTM D 412) Tensile strength >1.5 Ν/mm2 (ASTM D 412) Capillary water absorption 0.01kg/m2.h0.5 (EN 1062-3, requirement ΕΝ 1504-2: w < 0,1) Permeability sD to CO2, per EN 1062-6 sD > 50m Water vapour permeability sD per EN ISO 7783 sD = 1.73m (water vapour class I, sD < 5m) Adhesion to concrete per EN 1542 1.2 N/mm² (requirement for flexible systems without circulation: 0.8 N/mm²) Impact resistance per EN ISO 6272-1 5Νm (class I) Application temperature From +5˚C to +35˚C Temperature resistance From -25˚C to +80˚C